CCF vs. therms: checking commercial property gas bills

Reconcile gas volume, therms and billing rates before comparing commercial property expenses. Includes a worked example and a copyable review worksheet.

Pillar team4 min read

To compare commercial property gas bills, keep volume and energy in separate columns. CCF measures hundreds of cubic feet; a therm measures 100,000 Btu of energy. Convert with the factor documented for the bill, then apply a rate expressed in the matching unit. A number copied from a meter record may need conversion before it belongs next to a price per therm.

This guide gives acquisition and property teams a way to check that arithmetic. It does not estimate a building's future gas demand or replace the utility's tariff.

Find the unit before comparing the price

EIA explains that converting natural gas prices between volume and energy requires the gas's heat content. That heat content can vary by location and over time. A national average is useful for broad comparisons, but the supplier's information is the better starting point for reconciling a particular bill. EIA natural gas price conversions

The basic units are:

  • CCF: 100 cubic feet of gas.
  • Mcf: 1,000 cubic feet, or 10 CCF.
  • Therm: 100,000 Btu.

EIA's energy units guide explains the distinction between physical quantities and heat content. Keep the capitalization and units shown on the source record in your worksheet so someone else can trace the entry.

Use the conversion shown for the billing period

Look for a therm factor or multiplier in the bill detail. PG&E describes its therm factors as converting metered volume in hundreds of cubic feet into therms. Its bill guide identifies the multiplier used to convert the meter-read difference into therms. Other suppliers may present this differently. PG&E therm-factor FAQ, PG&E bill guide

If a bill already reports therms, do not apply a volume-to-energy factor to that number again. Record the original reading, the unit and the billed therms separately. Ask the utility about unexplained differences instead of adjusting a factor until the spreadsheet matches.

For volume already expressed in CCF, and a factor expressed in therms per CCF:

Therms = CCF × therms-per-CCF factor
Energy charge = therms × dollars per therm

The second equation calculates only the charge represented by that rate. It does not establish the total invoice, which must be reconciled to its own line items.

Worked example: a unit mismatch changes the result

The following figures are hypothetical. They are chosen to show the calculation, not quoted from a property or a current tariff.

Assume a bill records 2,500 CCF, a factor of 1.035 therms per CCF and a single energy charge of $1.10 per therm.

2,500 CCF × 1.035 therms/CCF = 2,587.5 therms
2,587.5 therms × $1.10/therm = $2,846.25

Multiplying 2,500 directly by $1.10 produces $2,750. The $96.25 difference comes from mixing a volume quantity with an energy price.

This example also works as a reverse check. Divide $2,846.25 by 2,587.5 therms and the rate returns to $1.10 per therm. Divide it by 2,500 CCF and the equivalent price is $1.1385 per CCF. Both prices describe the same hypothetical charge under the stated factor.

Neither number is a forecast. A different period can have a different consumption quantity, factor or rate.

Copyable gas-bill review worksheet

Use one record per meter and service period. The template below is an editorial review aid; it is not a utility form.

Property:
Utility / supplier:
Meter identifier:
Source invoice filename:
Service start and end dates:

Original reported quantity:
Original reported unit:
Already reported in therms? Yes / No
Documented conversion factor and units:
Where the factor appears on the bill:
Calculated therms:
Billed therms:
Difference and explanation:

Charge being checked:
Rate and rate unit:
Calculated charge:
Invoice charge:
Other invoice lines excluded from this calculation:
Rounding or adjustment noted by supplier:
Unresolved question / person responsible:
Reviewed on:

Keep the original bill beside the completed worksheet. If the seller supplies only an annual expense total, request the underlying meter history before treating that total as a consumption measure.

For comparisons across properties, use matching service periods and document what each meter serves. A reconciled gas quantity still needs operational context: a restaurant kitchen, central hot-water system and intermittently occupied warehouse have different uses for gas. This worksheet checks the numbers you received; evaluating those operations is a separate task.

Include the unresolved items in the acquisition file

A useful handoff identifies which bills reconcile and which require follow-up. For each exception, retain the source quantity, the calculation and the unanswered question. Avoid silently replacing a missing factor with a portfolio-wide assumption.

Use this operating-record review alongside the earlier property checks in the desktop site-screening checklist. If you are comparing land alternatives before an operating building exists, the land acquisition software guide addresses a different stage of that research.