Garden-style apartments are low-rise apartment communities with landscaped grounds and usually surface parking. Many have several buildings and walk-up entrances. Published descriptions typically put them at one to four stories, and the layout is often associated with suburbs. The term describes the whole property, not one unit.

By Pillar, a land research software company. Sources read November 25, 2026. General information, not legal or design advice: confirm a site's rules with the local planning and building departments and a licensed professional in its state.

What is a garden-style apartment?

Publishers use different cutoffs. ButterflyMX says "usually one to four stories." Swiftlane says "typically one to three stories."

Overland Park, Kansas, defines a garden apartment building in its zoning code as "an apartment building located on a lot either singly or together with other similar apartment buildings, such buildings generally being one or two stories in height and having grounds completely landscaped" (section 18.110.280).

What does a garden-style apartment complex look like?

  • Several low buildings. Swiftlane describes "multiple buildings spread across a landscaped site."
  • Doors that open outdoors. ButterflyMX says many are walk-up buildings, where residents reach their units from outdoor stairs, breezeways or exterior corridors.
  • Surface parking. Swiftlane says surface lots or carports sit near each building instead of in a centralized garage.

Garden-style vs. mid-rise and high-rise apartments

Swiftlane's comparison table puts garden style at 1 to 3 stories, mid-rise at 4 to 6 and high-rise at 7 or more.

Pros and cons for renters

ButterflyMX says a garden-style community can offer easier parking, often with a shorter walk from the car to the building, plus more green space, simpler pet routines and less reliance on elevators in low-rise walk-ups. Outdoor doors, stairs, breezeways and sidewalks can expose renters to more rain, snow, heat or cold. Spread-out sites can mean longer walks to mail, trash areas, amenities, leasing offices or package pickup. Rent may be lower in some markets, depending on location, age, finishes and amenities. ButterflyMX says neither garden-style communities nor high-rises are automatically safer or better.

Garden apartment vs. garden-level apartment

Redfin says a garden apartment usually means a complex with shared green space and apartment buildings up to three stories tall. In East Coast markets such as Boston and Brooklyn, it says the term usually refers to a ground-floor unit with direct access to a private garden or patio. ButterflyMX uses "garden level" for a unit's position, usually at ground level or partly below it. Ask which meaning the listing uses and whether the outdoor space is private or shared.

What renters should ask: stairs, elevators and parking

Stairs and elevators. Ask whether the building has an elevator, which floor the unit is on and how many steps lead to its door. For buildings with at least four dwellings, HUD's definition covers all units in elevator buildings and ground-floor units in other buildings. A ground floor has an entrance on an accessible route, and a building can have more than one (24 CFR 100.201). For covered multifamily dwellings designed and built for first occupancy after March 13, 1991, §100.205 requires at least one building entrance on an accessible route unless terrain or unusual site characteristics make that impractical. The designers or builders must establish impracticality. The rule treats a dwelling as designed and built for first occupancy on or before March 13, 1991 if it was occupied by then or if a state, county or local government issued its last building permit or renewal on or before June 15, 1990. In HUD's example, a three-story building has 30 garden apartments, no elevator and one accessible entrance on the first floor. Only the first-floor units are covered. They must meet §100.205(c) and have access to at least one of each type of public or common use area available to residents.

Parking. Ask whether spaces are assigned, covered or included in the rent, and where guests park.

How many units per acre? What one zoning code allows

There is no national figure. Each zoning code sets its own limits. Overland Park, Kansas, names two districts for the format: the R-3 Garden Apartment District and the RP-3 Planned Garden Apartment District.

Overland Park §18.210.020(B) lists garden apartment buildings in R-3 and RP-3, subject to §18.210.050. Section 18.210.050 requires adequate sanitary sewers available for connection. Pedestrian routes must be located and designed for adequate physical separation from vehicles along all public and private streets and drives and within any parking area. Design, grade and build site drainage to keep surface runoff from pooling on or crossing pedestrian paths, walks and sidewalks. Site plan approval under Chapter 18.140 comes before any building permit. RP-3 development or redevelopment requires approved preliminary and final development plans under §18.140.200. Under §18.150.070(A), the city may exclude otherwise permitted uses from a development through plan conditions if it finds the exclusion reasonably necessary for public health, safety and general welfare.

  • Density. Section 18.210.030, which applies except as chapter 18.420 provides, sets "Net site area per multi-family dwelling unit -- 3,500 square feet (12.4 units per net acre)." Net site area is the land left "after subtraction of all public street and alley rights-of-way as are required by this ordinance" (section 18.110.435).
  • Height. The same section sets a three-story maximum, with the three-story portion of any building set back at least 50 feet from any adjacent streets or single-family residential development.
  • Coverage. Overland Park §18.210.050(B) caps lot coverage at 50% of net site area. Under §18.110.380, count structure ground floors, parking lots, and private streets and drives. Pools, tennis courts, sidewalks and plazas are excluded.
  • Parking. The base ranges in §18.430.150 are 1–2 spaces per unit in Area A and 1–2.5 in Area B. Under §18.430.160, projects with direct access to the street dividing the areas can use either range. Before relying on a parking ratio outside the applicable range, read §§18.430.170 and 18.430.200.

For how other codes set multifamily density, see R3 zoning and R4 zoning.

2024 IBC height and story limits for wood construction

The building code limits how tall a wood-frame apartment building can be. The contractor LandSouth Construction describes garden-style as "2 to 4 stories of all-wood-frame buildings over surface parking."

The International Building Code (IBC) is a model code that states and cities adopt with their own amendments, so the locally adopted edition governs. We read the 2024 limits for wood construction as excerpted in 2024 Code Conforming Wood Design, published by the American Wood Council and the International Code Council (apartments as Group R-2 on page 4, construction types on pages 6 and 8, table excerpts in Figure 16 on pages 10 and 11, Section 510 on pages 19 and 20).

  • Occupancy. Apartments are Group R-2. A table note says new Group R occupancies must be protected by an automatic sprinkler system under Section 903.2.8.
  • Type V construction. Type V allows wood and other materials approved by the code. Table 601 gives Type VA base one-hour ratings for the primary frame, bearing walls, floors and roof construction, and gives Type VB zero-hour base ratings for those elements. Apply the table footnotes and other code requirements, including exterior-wall ratings based on fire separation distance.
  • Stories and height. Table 504.4 lists four stories above grade plane for Type VA and three for Type VB for Group R-2 buildings sprinklered throughout with NFPA 13 or 13R. Table 504.3 lists base heights above grade plane of 70 feet for VA and 60 for VB with NFPA 13, and 60 feet for both with NFPA 13R. For NFPA 13R, §903.3.1.2 requires four stories or fewer above grade plane, a roof assembly less than 45 feet above the lowest level of fire department vehicle access, and a lowest-story floor no more than 30 feet below that level. For the roof measurement, measure from the lowest required fire vehicle access road surface next to the building to the eave of the highest pitched roof, the intersection of the highest roof and exterior wall, or the top of the highest parapet. Use the greatest distance. For Group R projects under §§510.2 and 510.4, count stories from grade plane for this sprinkler test. The wood design publication reprints the three conditions in Table 15, note d, page 72.

For an NFPA 13-sprinklered Group R-2 building, the base Type IIIA limits in Tables 504.4 and 504.3 are five stories and 85 feet. IBC §602.3 calls for noncombustible Type III exterior walls and allows fire-retardant-treated wood framing and sheathing that comply with §2303.2 in exterior wall assemblies rated two hours or less. Check the required assembly rating separately.

IBC §510.2 provides a conditional podium option. When all its requirements are met, the code treats the portions above and below the horizontal assembly that separates them as separate buildings for story limits, construction type, area and fire-wall continuity. The total height from grade plane still follows the smaller of the two §504.3 height limits.

How much land does a garden-style project need?

Take a hypothetical site of 10 to 20 net acres in Overland Park's R-3 district. It is not a real parcel. The counts are our arithmetic, not the city's determination. Assume one lot. Section 18.150.060(A) generally calls for a planned district when a garden apartment project would split the site into multiple lots.

  • Units. An acre is 43,560 square feet. Ten net acres is 435,600 square feet; divided by 3,500, that is 124.5. Twenty net acres is 871,200 square feet, or 248.9. For this illustration, count only whole units backed by 3,500 square feet each. The base density calculation gives 124 units on 10 net acres and 248 on 20.
  • Parking spaces. At 124 units, the base range is 124 to 248 spaces in Area A and 124 to 310 in Area B. At 248 units, it is 248 to 496 and 248 to 620.
  • Coverage. At 50%, building ground floors, parking lots and private streets and drives can together cover at most 5 of the 10 net acres, or 10 of the 20.
  • Not in the arithmetic. Building setbacks under section 18.210.030(A)(1) and (B) and parking setbacks under section 18.430.070 use the same land.

Run it backward: 200 units times 3,500 square feet is 700,000 square feet. A 200-unit target needs about 16.1 net acres under the density calculation alone. Check setbacks, sewer availability, stormwater, floodplain, wetlands and easements separately to see how they affect the layout.

How many new multifamily buildings are low-rise?

The Census Bureau's Characteristics of New Housing tables group new multifamily buildings by number of floors. Of an estimated 17,000 privately owned multifamily buildings completed in 2025, 32% had one or two floors and 46% had three. That leaves about 22% with four or more, calculated from the published rounded shares (2025 highlights).

Counted by units, the picture reverses. Of 484,000 multifamily units completed in 2025, 7% were in buildings with one or two floors, 32% in three-floor buildings and 61% in buildings with four floors or more, according to the same page.

These sample-based estimates cover new, privately owned multifamily construction completed in 2025. Two-unit buildings accounted for 20% of the estimated building total. The floor categories describe building height in floors and do not identify garden-style properties.

What to check on a site before an offer

  1. The district and the use. Find the parcel on the official zoning map, then read the district chapter. Is the apartment use permitted, conditional or prohibited, and what approval comes before a permit?
  2. The acreage the density uses. Subtract required public street and alley rights-of-way, then divide the remaining square feet by 3,500 for the Overland Park base density calculation. Elsewhere, ask the surveyor for the figure the local code uses. Then check mapped floodplain and wetlands (Flood Zone X, wetland delineation).
  3. Sewer and water. Ask the provider whether it can serve the unit count, and what a will-serve letter confirms.
  4. Stormwater and coverage. Check impervious surface limits and where a detention or retention pond would go.
  5. Traffic. Ask whether the unit count triggers a traffic impact study.
  6. The building code. Ask the building department which edition and amendments apply.

In the deal documents, read the title commitment's exceptions and the recorded plat for easements and dedicated right-of-way.

Pillar shows a parcel's available zoning facts and acreage on the parcel record, and mapped FEMA flood zones and National Wetlands Inventory wetlands over parcel boundaries (Pillar for multifamily). Zoning and infrastructure layers need a paid plan or an active Pro trial, and coverage varies by dataset. Pillar does not determine what can be built on a site.

For the wider process, see multifamily development and the desktop site screening checklist. For other ways to arrange homes on a site, see townhome development and the build-to-rent guide's comparison of platted lots and horizontal apartments.

Quick answers

What is a garden-style apartment? An apartment in a garden-style community: a low-rise property on landscaped grounds, usually with surface parking and often several buildings. Published descriptions typically put these properties at one to four stories. The term describes the property, not the unit.

Is a garden apartment the same as a garden-level apartment? Not always. Redfin says a garden apartment usually means a complex with shared green space and apartment buildings up to three stories tall. In East Coast markets such as Boston and Brooklyn, it says the term usually refers to a ground-floor unit with direct access to a private garden or patio. ButterflyMX uses "garden level" for a unit's position, usually at ground level or partly below it.

Do garden-style apartments have elevators? ButterflyMX's answer is "Usually not," though it says some newer or specialized properties may include them.

How many units per acre are garden-style apartments? It depends on the zoning code. In Overland Park's R-3 and RP-3 districts, §18.210.030(C) sets a base minimum of 3,500 square feet of net site area per multifamily dwelling, expressed in the code as 12.4 units per net acre. Check Chapter 18.420 and any applicable approved development plan.

How much parking do garden-style apartments need? The local code decides. Overland Park's base ranges in §18.430.150 are 1–2 spaces per unit in Area A and 1–2.5 in Area B. For parking outside the applicable range, see the provisions cited above.